HydroBios / Products / Membrane Elements / Residential Membrane Elements




Residential Membrane Elements

Are recognized as one of the industry?s most reliable and highest performing membrane elements that deliver consistent performance and quality. Advanced membrane technology and manufacturing processes allow these elements to deliver consistent results that water treatment equipment suppliers, distributors and dealers have come to rely on.

CARACTERISTIQUES GLOBALES

  • Membrane Type: Thin Film Composite
  • Maximum Operating Temperature : 43°C (110°F)
  • Maximum Operating Pressure : 9 bars (125psi)
  • Maximum Flow Rate : 3.78 litres minute (1GPM)
  • Minimum concentrate Flow Rate : 4 x permeate
  • pH Range continuous operation : 3-11
  • Maximum Feed turbidity : 1 NTU
  • Maximum Silt Density Index : 5 SDI
  • Chlorine Tolerance : < 0ppm

Code

description

Applied Pressure psig/bar

Product in GPD / LPJ

nominal rejection %

1D1004

12 GPD TFC

60 / 4.1

12 / 45

98

1D1005

18 GPD TFC

60 / 4.1

18 / 68

98

1D1006

25 GPD TFC

60 / 4.1

25 / 95

98

1D1007

35 GPD TFC

60 / 4.1

35 / 132

98

1D1008

50 GPD TFC

60 / 4.1

50 / 189

98

1D1009

70 GPD TFC

60 / 4.1

70 / 265

98

1D1010

100 GPD TFC

60 / 4.1

100 / 379

98

Permeate flow and salt rejection based on the following test conditions: 550 ppm Treated Tap Water, 77°F (25°C), 15% Permeate Recovery, 6.5 ? 7.0 pH Range, and the specified applied pressure. Data taken after 30 minutes of operation. Maximum pressure drop for each element is 10 psi. Minimum salt rejection is 96%. Permeate flow for individual elements may vary +/- 20%.

Wet tested membrane elements must be kept sealed and moist when in storage. Drying out may occur and damage the membrane permanently. Prevent elements from freezing or being exposed to direct sunlight. Wet tested elements are vacuum sealed in a polyethylene bag containing 1.0% sodium meta-bisulfite and then packaged in a cardboard box. Discard the permeate for the first two hours of operation. The permeate flow (product water flow) varies with feed water temperature. Review a Temperature Correction Chart. For membrane warranty information, please contact manufacturer.
The manufacturer believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith, but without guarantee, as conditions and methods of use of products are beyond the manufacturer?s control. The manufacturer assumes no liability for results obtained or damages incurred through the application of the presented information and data. It is the user?s responsibility to determine the appropriateness of the products for the user?s specific end uses.