HR3 reverse osmosis membrane elements are the industry's most reliable and highest performing elements. HR3 Membrane Elements deliver consistent high performance results day in and day out. Advanced membrane technology and manufacturing processes allow these elements to deliver consistent performance that equipment suppliers and water treatment dealers can rely on.
|
PRODUCT SPECIFICATIONS |
|||||
|
CODE |
Description |
Applied Pressure psig / bar |
Maximum pressure psig / bar |
Permeate Flow Rate (GPD) |
Nominal % Rejection |
|
1D2061 |
2514 TFC HR3 |
225 / 15.51 |
400 / 27.58 |
150 |
99.0 |
|
1D2062 |
2521 TFC HR3 |
225 / 15.51 |
400 / 27.58 |
250 |
99.0 |
|
1D2063 |
2540 TFC HR3 |
225 / 15.51 |
400 / 27.58 |
650 |
99.0 |
|
1D2064 |
4014 TFC HR3 |
225 / 15.51 |
400 / 27.58 |
400 |
99.0 |
|
1D2065 |
4021 TFC HR3 |
225 / 15.51 |
400 / 27.58 |
900 |
99.0 |
|
1D2066 |
4040 TFC HR3 |
225 / 15.51 |
400 / 27.58 |
2200 |
99.0 |
|
Permeate flow and salt rejection based on the following test conditions: 550 ppm Treated Tap Water, 77°F (25°C), 15% Permeate Recovery, 6.5 - 7.0 pH Range, and the specified applied pressure. Data Taken after 30 Minutes of Operation. Maximum Pressure Drop for Each Element is 10 psi. Minimum salt rejection is 96%. |
|||||
Operating Limits:
|
DIMENSIONS (INCHES) |
||||
|
Description |
A |
B |
C |
D |
|
2514 TFC HR3 |
14 |
1.0 |
0.75 |
2.4 |
|
2521 TFC HR3 |
21 |
1.0 |
0.75 |
2.4 |
|
2540 TFC HR3 |
40 |
1.0 |
0.75 |
2.4 |
|
4014 TFC HR3 |
14 |
1.0 |
0.75 |
3.95 |
|
4021 TFC HR3 |
21 |
1.0 |
0.75 |
3.95 |
|
4040 TFC HR3 |
40 |
1.0 |
0.75 |
3.95 |
Permeate flow for individual elements may vary +/- 15%. Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, HydroBios recommends removing residual free chlorine by pretreatment prior to membrane exposure. Wet tested membrane elements must be kept sealed and moist when in storage. Drying out may occur and damage the membrane permanently. Prevent elements from freezing or being exposed to direct sunlight. Elements are vacuum sealed in a polyethylene bag containing 1.0% sodium meta-bisulfite and then packaged in a cardboard box. Discard the permeate for the first two hours of operation. The permeate flow (product water flow) varies with feed water temperature. Review our Temperature Conversion Chart. For membrane warranty information, review our Warranty for Reverse Osmosis Membrane Elements.
HydroBios believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith, but without guarantee, as conditions and methods of use of our products are beyond our control. HydroBios assumes no liability for results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the appropriateness of HydroBios' products for the user's specific end uses.